PENGARUH WAKTU PEMERIKSAAN GLUKOSA DARAH MENGGUNAKAN TABUNG PLAIN DAN TABUNG SERUM SEPARATOR

Authors

  • Qonita Ardiyanti Maysarah Politeknik Kesehatan Kementrian Kesehatan Surabaya
  • Anik Handayati Politeknik Kesehatan Kementrian Kesehatan Surabaya
  • Museyaroh Museyaroh Politeknik Kesehatan Kementrian Kesehatan Surabaya
  • Evy Diah Woelansari Politeknik Kesehatan Kementrian Kesehatan Surabaya

DOI:

https://doi.org/10.51878/healthy.v5i4.14080

Keywords:

Glukosa Darah, Penundaan Pemeriksaan, Tabung Plain, Tabung Serum Separator

Abstract

Blood glucose testing is one of the most important laboratory examinations for the diagnosis, monitoring, and evaluation of diabetes mellitus management. The accuracy of test results is influenced by various factors, particularly those occurring during the pre-analytical phase, including the type of blood collection tube used and the delay between sample collection and analysis. Delayed examination may reduce blood glucose concentration due to ongoing glycolysis within blood cells, thereby affecting the validity of laboratory results. This study aimed to analyze the effect of delayed examination time on blood glucose levels using plain tubes and Serum Separator Tubes (SST). An experimental study with a Two-Way Repeated Measures design was conducted. Serum samples obtained from seven respondents were collected into plain tubes and SST tubes and analyzed at 0, 5, and 10 hours using a Biobase Automatic Chemistry Analyzer. Data were analyzed using the Shapiro–Wilk normality test and Two-Way Repeated Measures ANOVA. The results showed that the mean blood glucose level in plain tubes decreased from 75.57 mg/dL at 0 hours to 64.29 mg/dL at 5 hours and 65.43 mg/dL at 10 hours. In contrast, blood glucose levels in SST tubes remained relatively stable at 75.71 mg/dL, 76.86 mg/dL, and 78.14 mg/dL at 0, 5, and 10 hours, respectively. The data were normally distributed (p > 0.05). Two-Way Repeated Measures ANOVA demonstrated that examination time, tube type, and their interaction had a statistically significant effect on blood glucose levels (p < 0.05). These findings indicate that delayed examination affects blood glucose levels in plain tubes, whereas SST tubes are able to maintain blood glucose stability for up to 10 hours after sample collection.

ABSTRAK

Pemeriksaan kadar glukosa darah merupakan salah satu pemeriksaan laboratorium yang berperan penting dalam menegakkan diagnosis, memantau perkembangan penyakit, serta mengevaluasi keberhasilan terapi pada pasien diabetes mellitus. Keakuratan hasil pemeriksaan dipengaruhi oleh berbagai faktor, khususnya pada tahap pra-analitik, seperti jenis tabung yang digunakan dan lamanya waktu antara pengambilan sampel dengan proses pemeriksaan. Penundaan pemeriksaan dapat menyebabkan penurunan kadar glukosa akibat proses glikolisis yang masih berlangsung di dalam sel darah sehingga memengaruhi validitas hasil pemeriksaan. Penelitian ini bertujuan untuk menganalisis pengaruh penundaan waktu pemeriksaan terhadap kadar glukosa darah menggunakan tabung plain dan Serum Separator Tube (SST). Penelitian menggunakan desain eksperimen dengan pendekatan Two Way Repeated Measure. Sampel berupa serum dari tujuh responden yang dimasukkan ke dalam tabung plain dan SST, kemudian dianalisis pada waktu 0 jam, 5 jam, dan 10 jam menggunakan Biobase Automatic Chemistry Analyzer. Analisis data dilakukan menggunakan uji normalitas Shapiro-Wilk dan uji Two Way Repeated Measure ANOVA. Hasil penelitian menunjukkan bahwa rerata kadar glukosa pada tabung plain mengalami penurunan dari 75,57 mg/dL pada 0 jam menjadi 64,29 mg/dL pada 5 jam dan 65,43 mg/dL pada 10 jam. Sebaliknya, kadar glukosa pada tabung SST tetap relatif stabil, yaitu 75,71 mg/dL, 76,86 mg/dL, dan 78,14 mg/dL pada masing-masing waktu pengamatan. Data penelitian berdistribusi normal (p>0,05). Hasil analisis menunjukkan bahwa waktu pemeriksaan, jenis tabung, serta interaksi keduanya memberikan pengaruh yang bermakna terhadap kadar glukosa darah (p<0,05). Dengan demikian, penundaan pemeriksaan menyebabkan perubahan kadar glukosa pada tabung plain, sedangkan penggunaan tabung SST mampu mempertahankan stabilitas kadar glukosa darah hingga 10 jam setelah pengambilan sampel.

References

Agustin, L. D., Istiqomah, I. N., & Mashuri. (2022). Management of blood glucose levels in type 2 diabetes mellitus patients through Ramadan fasting: A literature review: Manajemen kadar glukosa darah pasien diabetes mellitus tipe 2 melalui puasa Ramadhan: Literatur review. Jurnal Kesehatan Komunitas Indonesia, 2(1), 78–91. https://doi.org/10.58545/jkki.v2i1.23

Azizah, F. N., Haryanto, E., & Astuti, S. S. E. (2023). Pengaruh variasi waktu penundaan pemisahan serum terhadap hasil pemeriksaan glukosa. The Journal of Muhammadiyah Medical Laboratory Technologist, 6(2), 184–191. https://doi.org/10.30651/jmlt.v6i2.14594

Care, D., & Suppl, S. S. (2024). Diagnosis and classification of diabetes: Standards of care in diabetes—2025. Diabetes Care, 47(January), S27–S49. https://doi.org/10.2337/dc25-S002

Dibbasey, M., Umukoro, S., & Bojang, A. (2024). Comparative and stability study of glucose concentrations measured in both sodium fluoride and serum separator tubes. Practical Laboratory Medicine, 39, e00360. https://doi.org/10.1016/j.plabm.2024.e00360

Fernández Prendes, C., Castro Castro, M. J., Sánchez Navarro, L., Rapún Mas, L., Morales Indiano, C., & Arrobas Velilla, T. (2023). Handling of lipemic samples in the clinical laboratory. Advances in Laboratory Medicine, 4(1), 5–15. https://doi.org/10.1515/almed-2023-0003

Gunawan, H. A. (2024). Perbandingan kadar glukosa darah menggunakan sampel serum, plasma heparin dan plasma NaF. Jurnal Wiyata: Penelitian Sains dan Kesehatan, 11(1), 36. https://doi.org/10.56710/wiyata.v11i1.785

Hardianto, D. (2021). Telaah komprehensif diabetes melitus: Klasifikasi, gejala, diagnosis, pencegahan, dan pengobatan. Jurnal Bioteknologi & Biosains Indonesia (JBBI), 7(2), 304–317. https://doi.org/10.29122/jbbi.v7i2.4209

He, L., Zheng, W., Li, Z., Chen, L., Kong, W., & Zeng, T. (2023). J-shape relationship between normal fasting plasma glucose and risk of type 2 diabetes in the general population: Results from two cohort studies. Journal of Translational Medicine, 21(1), 1–10. https://doi.org/10.1186/s12967-023-04006-9

Kosmas, C. E., Bousvarou, M. D., Kostara, C. E., Papakonstantinou, E. J., Salamou, E., & Guzman, E. (2023). Insulin resistance and cardiovascular disease. Journal of International Medical Research, 51(3), 1–49. https://doi.org/10.1177/03000605231164548

Nakanga, W. P., Balungi, P., Niwaha, A. J., Shields, B. M., Hughes, P., Andrews, R. C., McDonald, T. J., Nyirenda, M. J., & Hattersley, A. T. (2022). Alternative pre-analytic sample handling techniques for glucose measurement in the absence of fluoride tubes in low resource settings. PLoS ONE, 17(2), 1–7. https://doi.org/10.1371/journal.pone.0264432

Nevraumont, A., Deltombe, M., & Bayart, J.-L. (2024). How pre-analytical conditions impact glucose measurement and (gestational) diabetes diagnosis: A real-world stability study and a call for harmonization. Clinica Chimica Acta, 562, 119875. https://doi.org/10.1016/j.cca.2024.119875

Prihandono, D. S., Kesuma, S., & Widyadari, E. R. (2024). Evaluasi penggunaan serum dan plasma yang disimpan pada tabung clotting activator dan NaF selama 6 dan 24 jam parameter glukosa darah. Jambura Journal of Health Sciences and Research, 6(3), 277–287. https://doi.org/10.35971/jjhsr.v6i3.21870

Primasyukra, M. A., Vernando, G., Hasibuan, V., Situmorang, H., & Sijabat, S. (2025). Analisa uji fungsi alat HbA1c. Jurnal Mutiara Elektromedik, 9(1), 40–45. https://garuda.kemdiktisaintek.go.id/documents/detail/5308428

Purwaningsih, N. V., Maulidiyanti, E. T. S., Surohadi, N. D., Muzammil, A., Wijiastuti, B., & Fitriyah, L. (2025). Faktor pre-analitik pemeriksaan glukosa 2 jam PP pada pasien diabetes mellitus di RSU Haji Provinsi Jawa Timur Surabaya. Jurnal Media Analis Kesehatan, 16(1), 19–25. https://doi.org/10.32382/jmak.v16i1.1101

Santosa, W. R. B., & Akasyah, W. (2024). Hubungan kepatuhan diet dan gaya hidup terhadap kadar gula darah pada pasien diabetes mellitus tipe 2 (Relationship between diet compliance and lifestyle with blood sugar levels in type 2 diabetes mellitus patients). Jurnal Wiyata: Penelitian Sains dan Kesehatan, 11(2), 158–164. https://doi.org/10.56710/wiyata.v11i2.851

Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Lernmark, Å., Metzger, B. E., Nathan, D. M., & Kirkman, M. S. (2023). Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus. Clinical Chemistry, 69(8), 808–868. https://doi.org/10.1093/clinchem/hvad080

Shafa Nabilah, Khotimah, E., & Pramitaningrum, I. K. (2023). Pemantapan mutu internal pra-analitik pada pemeriksaan glukosa darah puasa di Laboratorium Duren Sawit. Binawan Student Journal, 5(2), 58–64. https://doi.org/10.54771/bsj.v5i2.1127

Shoaib, M., Muzammil, I., Bhutta, Z. A., Yaseen, I., Munir, H., Ali, M., Younas, M. S., Ahmad, S., & Mahtab, U. (2020). Pre-analytical errors and rejection criteria for blood samples in hematology laboratory. Journal of Agriculture, Food, Environment and Animal Sciences, 1(1), 39–49. https://www.jafeas.com/index.php/j1/article/view/8

Sutrisno, D., & Sudrajat, A. (2024). Pengaruh lama penundaan terhadap hasil pengukuran kadar serum glukosa darah. Jurnal Infokes, 8(1). https://doi.org/10.56689/infokes.v8i1.1366

Venna, V., Wijaya, J., Singgih, G., & Ardianto, C. (2023). Perbandingan pemeriksaan kadar glukosa darah mandiri dengan uji laboratorium menggunakan metode baku emas. Damianus Journal of Medicine, 22, 147–152. https://doi.org/10.25170/djm.v22i2.4235

Widiasari, K. R., Wijaya, I. M. K., & Suputra, P. A. (2021). Diabetes melitus tipe 2: Faktor risiko, diagnosis, dan tatalaksana. Ganesha Medicina Journal, 1(2), 114–120. https://doi.org/10.23887/gm.v1i2.40006

Downloads

Published

2026-08-23

How to Cite

Maysarah, Q. A., Handayati, A., Museyaroh, M., & Woelansari, E. D. (2026). PENGARUH WAKTU PEMERIKSAAN GLUKOSA DARAH MENGGUNAKAN TABUNG PLAIN DAN TABUNG SERUM SEPARATOR. HEALTHY : Jurnal Inovasi Riset Ilmu Kesehatan, 5(4), 861–868. https://doi.org/10.51878/healthy.v5i4.14080